EPV.SC (KFV.SC) fiberglass, cellulose and polypropylene pleated filter cartridges and capsules for effective protection of membrane cartridges and clarifying filtration of liquids

Description 

The EPV.SC cartridges are produced on the basis of the pleated filter material made of microfine glass, cellulose and polypropylene fibers. Efficient filtration is achieved by means of high adsorption of fiberglass and cellulose and diversity of chemical nature of microfibers in combination with mechanical retention.

Benefits 

Features

Advantages

Glass, cellulose and polypropylene microfibers based pleated cartridge

  • High filtration efficiency (> 99%).
  • Stable biochemical properties.
  • Increased contamination capability and lifetime provide long-term operation without regenerations.
  • Excellent hydrophilicity of fibers ensures filtration under minimal differential pressure (even by gravity flow).
  • Designed for highly efficient clarifying filtration and protection of membrane filters.
  • Produced with with 0.2, 0.5, 0.8 and 1 μm ratings.
  • Higher flow rates at low hydraulic resistance.

High strength, the stable matrix of the cartridge

  • Filter material structure precludes possibility of “dusting” and medium migration.
  • Withstand multiple wash outs and sterilizations.
  • Reliable filtration under heavy duty operational conditions.

Main applications

  • In medicine and biopharmaceuticals to reduce bacterial load before membrane cartridges, for fine clarifying filtration of pharmaceutical liquids with a high content of suspended particles, for filtration of high-viscosity liquids, syrups, galenic preparations.
  • In the food industry for preliminary and final filtration of wines, for clarification of colored liquor products, finishing stages of beer filtration and beer-soft drinks with the purpose of increasing the shelf life, for fine cleaning of technological, drinking, mineral and bottled water, etc .
  • In other industries for the retention of suspensions, microparticles and colloids with a size of 0.5-3.0 microns or more.

Nominal Dimensions

Filter carridges

Height (L), mm Diameter (D), mm

Filter Area (S), m2

125 (5’’)

70

0.25

250 (10’’)

70 0.5

500 (20’’)

70

1.0

750 (30’’)

70

1.5

1000 (40’’)

70

2.0

Capsule filters

Height (L), mm

Diameter (D), mm

Filter Area (S), m2

250 (10’’)

94

0.50

125 (5’’)

94

0.25

60 (2.5’’)

94

0.12

Operational parameters

Maximal differential pressure for cartridges, MPa

0.5 MPa at 20°C, 0.2 MPa at 80°C

Maximal differential pressure for capsules, MPa

0.4 MPa at 20°C, 0.2 MPa at 60°C

Maximal reverse differential pressure, MPa

0.2 MPa at 20°C

Maximal operational temperature, °C

90°C (for cartridges), 60°C (for capsules)

Direct flow wash out

Hot water (up to 80 °C) and chemical agents (pH 3-14), CIP

Autoclaving

121-132°С, 0.12 MPa, 30 min., 50 cycles (cartridges)

121°С, 0.12 MPa, 30 min., 10 cycles (capsules)

Steam sterilization

Up to 132°С, 30 min., 20 cycles

* For detailed instructions on wash out and sterilization of cartridges and capsules please contact technical specialists of Technofilter RME Ltd. 

Quality and Safety

EPV.SC filter cartridges are produced in accordance with the regulatory technical documents on product quality and are certified for use in the filtration processes of biopharmaceutical solutions. All EPV.SC filter cartridges are subjected to wash out from organic and mechanical impurities with high-purity water.

EPV.SC Filter Cartridges ordering information

EPV.SC

300/100

D1

500

M

Brand Micron rating Adapter code

Cartridge height

Application

 

 

050 = 0.2 μm

080 = 0.8 μm

100 = 1.0 μm

300/080 = 3.0 + 0.8 μm

300/100 = 3.0 + 1.0 μm

 

A (A1), A4, D (D1), B, B (Sl)

125 mm (5’’)

250 mm (10”)

500 mm (20”)

750 mm (30”)

1000 mm (40”)

M – medical and biopharmaceutical industry

P – food industry

E – microelectronics industry

KFV.SC Capsules ordering information

KFV.SC

300/080

K

125

Brand

Micron rating

Connection type

Capsule height

 

 

050 = 0.2 μm

080 = 0.8 μm

100 = 1.0 μm

300/080 = 3.0 + 0.8 μm

300/100 = 3.0 + 1.0 μm

 

K – sanitary flange connection

P – thread tapered  connection

60 mm (4”)

125 mm (5”)

250 mm (10”)


Back to top