RU | EN
contact phone +7 (4922) 47-47-41
About Us Products Application Quality Training and Service News Contact Feedback

EPNS stainless steel mesh pleated filter cartridge in polypropylene case for preliminary filtration of highly contaminated solutions and highly viscous liquids

Description

EPNS filter cartridges are cartridge type filters on the basis of the pleated material made of metal mesh (stainless steel AISI 304) with the effective filtration area from 0.22 to 1 m2. The pleated structure of the cartridge provides extended area of the surface compared to cylindrical metal filter cartridges, increasing thereby flow rates and lifetime of EPNS.

Benefits

Features

Advantages

Pleated, strong

  • High filtration rates and lifetime with low hydraulic resistance.
  • Mechanical strength of the element ensures multiple regenerations, wash outs and sterilizations in any direction.

High thermochemical resistance

  • Possibility to use elements for filtration of aggressive liquids under the temperatures up to 95 °C.
  • Withstand multiple chemical regeneration in a wide pH range and in-line steam sterilization.

Reliability

  • Ability to restore their operational properties ensures long element lifetime.
  • Produced in compliance with the Quality Management System (ISO 9001:2008).

Main applications

  • In medicine and biopharmaceuticals for preliminary filtration of highly viscous media, syrups, process water in ampoule washing machines.
  • In food industry for preliminary filtration in water treatment systems, clarification of syrups, cognacs, for mechanical treatment of alkaline solutions, alcohol, for clarification of syrups, oils, honey.
  • In other industries for treatment of aggressive liquids acids, alkaline, solvents and viscous media.

Nominal Dimensions

Filter cartridges

Height (L), mm

Diameter (D), mm

Filter Area (S), m2

250 (10’’)

70

0.22

500 (20’’)

70

0.44

750 (30’’)

70

0.66

1000 (40’’)

70

0.88

Operational parameters

Maximal differential pressure for cartridges, MPa

0.5 MPa at 20°C, 0.2 MPa at 80°C

Maximal operational temperature, °C

90°C

Direct and back flow wash out

Hot water (up to 95 °C) and chemical agents, CIP

Autoclaving and steam sterilization

In a wide range

*For detailed instructions on wash out and sterilization of cartridges and capsules please contact technical specialists of Technofilter RME Ltd.  

EPNS Filter Cartridges ordering information

EPNS

500

A1

500

Brand

Micron rating

Adapter code

Cartridge height

 

500 = 5.0 μm

1000 = 10 μm

2000 = 20 μm

4000 = 40 μm

7000 = 70 μm 

10000 = 100 μm

A (A1), A4, D (D1), B, B (Sl)

250 mm (10”)

500 mm (20”)

750 mm (30”)

1000 mm (40”)


Back to top