RU | EN
contact phone +7 (4922) 47-47-41
About Us Products Application Quality Training and Service News Contact Feedback

EPM.F hydrophobic fluoroplastic membrane filter cartridges for fine filtration of air, gases, aggressive liquids

 

Description

EPM.F membrane filter cartridges are produced on the basis of the fluoroplastic hydrophobic membrane with the micron rating of 0.45 - 0.8 μm. Filter cartridges have high throughput and chemical resistance to acids and solvents. Recommended to use for fine filtration of gaseous media and aggressive fluids.

Nominal Dimensions

Filter cartridges

Height (L), mm

Diameter (D), mm

Filter Area (S), m2

100 (4’’)

70

0.23

250 (10’’)

70

0.62

500 (20’’)

70

1.24

750 (30’’)

70

1.86

1000 (40’’)

70

2.48

Capsule filters

Height (L), mm

Diameter (D), mm

Filter Area (S), m2

250 (10’’)

94

0.62

125 (5’’)

94

0.3

60 (2.5’’)

94

0.12

Integrity test values of EPM.F

Brand

Bubble point (ethanol), MPa (bar)  

EPM.F - /045

0.036 (0.36)

EPM.F - /065

0.03 (0.3)

EPM.F - /080

0.02 (0.2)

*All values are given for the filter cartridges 10” (250 mm) height. To obtain maximum permissible diffusion values for filter cartridges 20” (500 mm) and 30” (750 mm) height the diffusion values for the standard (10”) cartridge should be multiplied by 2 or 3 respectively.    

Operational parameters

Maximal differential pressure for cartridges, MPa

0.5 MPa at 20°C, 0.2 MPa at 80°C

Maximal differential pressure for capsules, MPa

0.4 MPa at 20°C, 0.2 MPa at 60°C

Maximal operational temperature, °C

90°C (for cartridges), 60°C (for capsules)

Recommended gas flow rate (at 7 bar)  for the cartridge of 250 mm height, m3/h

300

Steam sterilization

121°С, 0.12 MPa, 30 min., 10 cycles (cartridges)

Autoclaving

121С, 0.12 MPa, 30 min., 50 cycles (cartridges)

121°С, 0.12 MPa, 30 min., 10 cycles (capsules)

* For detailed instructions on wash out and sterilization of cartridges and capsules please contact technical specialists of Technofilter. 

Quality and safety

EPM.F membrane filter cartridges are produced in accordance with the regulatory technical documents on product quality and are certified for use in the filtration processes of biopharmaceutical solutions. All EPM.F filter cartridges are subjected to purging from mechanical impurities with high-purity air and to 100% integrity control.  

Final assembly and packaging of membrane filter cartridges is carried out in special clean rooms (ISO class 5, 6 and 7) according to the classification of clean rooms in the pharmaceutical industry.  

EPM.F membrane filter cartridges undergo tests for bacterial and toxicological safety, materials used in the construction of filters have a minimal amount of extractable components and are approved for contact with intravenous drugs and food. Safety of filter cartridges is determined by a series of sanitary and chemical tests, and toxicology tests in compliance with GOST R ISO 10993.1-99, GOST R ISO 10993.5-99, GOST R ISO 10993.10-00.

EPM.F Filter Cartridges ordering information

EPM.F

045

D1

250

M

Brand

Micron rating

Adapter code

Cartridge height

Application

 

 

065/045 = 0.65 + 0.45 μm

065 = 0.65 μm

080/045 = 0.80 + 0.45 μm

080 = 0.80 μm

 

A (A1), A4, D (D1), B, B (Sl)

100 mm (4”)

250 mm (10”)

500 mm (20”)

750 mm (30”)

1000 mm (40”)

M – medical and biopharmaceutical industry

P – food industry

KFM.F Capsules ordering information

KFM.F

045

K

125

Brand

Micron rating

Connection type

Capsule height

 

 

065/045 = 0.65 + 0.45 μm

065 = 0.65 μm

080/045 = 0.80 + 0.45 μm

080 = 0.80 μm

 

K – sanitary flange connection

P – thread tapered  connection

60 mm (4”)

125 mm (5”)

250 mm (10”)


Back to top